Latching Relay-Charging pile-BX40A.2

  • 200A contact switching capability;
  • Only impulse excitation needed, both for single and double coil;
  • Low power consumption, small in size;
  • 4KV dielectric strength between contact and coil;
  • Mechanical Endurance>1million cycles.
  • Size:67*56.8*28.2(mm)
Purchase Contact
Data Download
Dear customer, hello:
If you need to consult more detailed product issues, please leave your contact information, and we will arrange professional personnel to provide you with further services. Thank you for your attention to Gretel intelligent products!

Continue downloading

Product appearance 3D structural diagram and other materials
file name remark update time
Parameters

Appearance Shell Color Black
contact Contact Form 1B(1A "1A" as default
Contact Material Silvery Alloy
Contact Resistance ≤0.8mΩ In accordance with the voltammetry test, 10A constant current is applied
Rated Load (Resistive) 200A/250VAC Rated Load (Resistive) 100A/150VDC
Max. Switching Voltage 250VAC Max. Switching Voltage(DC) 150VDC
Max. Switching Current 200A Max. Switching Current(DC) 100A
Max. Switching Power 50000VA Rated Switching Power 15000VA
coil Rated Voltage of Coil 12VDC
Initial Operating
Voltage
Closing 12VDC
Release 12VDC
Operating Time Closing ≤20ms single coil 12V drive
Release ≤20ms single coil 12V drive
Coil Resistance 18Ω±10% Customized
Impulse Width 100ms
Rated Power of Coil 8W
Performance Rated Working Temperature -40℃~70℃ At the limit temperature, it is required to work at the maximum operating frequency for 72H
Humidity 45%-90%RH
Mechanical Vibration 10~55HZ Single amplitude             0.35mm After the test, there should be no loose structure or mechanical damage, and the state of the relay can't be changed.
Mechanical Shock 500m/S2   11MS After the test, there should be no loose structure or mechanical damage, and the state of the relay can't be changed.
Insulation Resistance ≥1000MΩ 500VDC
Dielectric
Strength
Between
Contacts
3000VAC 1min No flashover, arcing or insulation breakdown is allowed during the dielectric withstand test. The leakage current shall not be greater than 1mA
Contact-Coil 4000VAC 1min

Performance Electrical Life 6×10³ On the condition of 150A/250VAC (resistive load, frequency reference standard), the number of continuous actions.
Mechanical Life 1×10⁵ The number of consecutive actions under no or light load conditions

How to order:

Dimension and Diagram(unit:mm)

Typical Installation Method