13390881265
xsb@greatrelay.cn
CN EN
Your current location: Index > Product

Latching Relay-BX80A1

  • 80A contact switch, super arc breaking ability
  • Withstand 1800A peak current (action time 10ms)
  • Product action time error ±0.2ms, consistency and stability
  • Dimension:33*30*17.3(L*W*H)
  • Widely used in DIN smart meters, over and under voltage protectors, etc
Purchase Contact
Data Download
Dear customer, hello:
If you need to consult more detailed product issues, please leave your contact information, and we will arrange professional personnel to provide you with further services. Thank you for your attention to Gretel intelligent products!

Continue downloading

Product appearance 3D structural diagram and other materials
file name remark update time
Parameters

Appearance Shell Color Black Remark
contact Contact Form 1B(1A "1B" as default
Contact Material Silvery Alloy
Contact Resistance ≤1.5mΩ In accordance with the voltammetry test, 10A constant current is applied
Rated Load (Resistive) 80A/250VAC
Max. Switching Voltage 250VAC
Max. Switching Current 80A
Max. Switching Power 20000VA
coil Rated Voltage of Coil 9VDC
Initial Operating
Voltage
Closing ≤9VDC
Release ≤9VDC
Operating Time Closing ≤20ms 9V drive
Release ≤20ms 9V drive
Coil Resistance 80Ω±10% Customized
Impulse Width 100ms
Rated Power of Coil 1.0W
Performance Rated Working Temperature -40℃~70℃ At the limit temperature, it is required to work at the maximum operating frequency for 72H
Humidity 45%-90%RH
Mechanical Vibration 10~55HZ Single amplitude 0.35mm After the test, there should be no loose structure or mechanical damage, and the state of the relay can't be changed.
Mechanical Shock 500m/S2   11MS After the test, there should be no loose structure or mechanical damage, and the state of the relay can't be changed.
Insulation Resistance ≥100MΩ 500VDC
Dielectric
Strength
Between
Contacts
2000VAC 1min No flashover, arcing or insulation breakdown is allowed during the dielectric withstand test. The leakage current shall not be greater than 1mA
Contact-Coil 4000VAC 1min

Performance Electrical Life 0.6×103 On the condition of 80A/250VAC (resistive load, frequency reference standard), the number of continuous actions.
Mechanical Life 1×105 The number of consecutive actions under no or light load conditions

How to order:

Dimension and Diagram(  unit:mm)

Typical Installation Method