13390881265
xsb@greatrelay.cn
CN EN
Your current location: Index > Product

Latching Relay-charging pile-BX120A.6

  • 120A contact switching capability;
  • Only impulse excitation needed, both for single and double coil;
  • Low power consumption, small in size;
  • Custom assemblies available according to Customer\\\'s requirements;
  • 4KV dielectric strength between contact and coil;
  • Mechanical Endurance>1million cycles.
  • Size:42.8*32*20.8(mm)
Purchase Contact
Data Download
Dear customer, hello:
If you need to consult more detailed product issues, please leave your contact information, and we will arrange professional personnel to provide you with further services. Thank you for your attention to Gretel intelligent products!

Continue downloading

Product appearance 3D structural diagram and other materials
file name remark update time
Parameters

Appearance Shell Color Black
contact Contact Form 1B(1A "1A" as default
Contact Material Silvery Alloy
Contact Resistance ≤1.0mΩ In accordance with the voltammetry test, 10A constant current is applied
Rated Load (Resistive) 120A/250VAC
Max. Switching Voltage 250VAC
Max. Switching Current 120A
Max. Switching Power 30000VA
coil Rated Voltage of Coil 15VDC
Initial Operating
Voltage
Closing ≤15VDC
Release ≤15VDC
Operating Time Closing ≤20ms single coil 15V drive
Release ≤20ms 15V drive
Coil Resistance 56Ω±10% Customized
Impulse Width 100ms
Rated Power of Coil 4W
Performance Rated Working Temperature -40℃~70℃ At the limit temperature, it is required to work at the maximum operating frequency for 72H
Humidity 45%-90%RH
Mechanical Vibration 10~55HZ Single amplitude             0.35mm After the test, there should be no loose structure or mechanical damage, and the state of the relay can't be changed.
Mechanical Shock 500m/S2   11MS After the test, there should be no loose structure or mechanical damage, and the state of the relay can't be changed.
Insulation Resistance ≥100MΩ 500VDC
Dielectric
Strength
Between
Contacts
2500VAC 1min No flashover, arcing or insulation breakdown is allowed during the dielectric withstand test. The leakage current shall not be greater than 1mA
Contact-Coil 4000VAC 1min

Performance Electrical Life 6×10³ On the condition of 120A/250VAC (resistive load, frequency reference standard), the number of continuous actions.
Mechanical Life 1×10⁵ The number of consecutive actions under no or light load conditions
How to order:

Dimension and Diagram(unit:mm)

Typical Installation Method