Solar Energy Relay-AX300

  • 300A contact overcurrent capability;
  • Contact gap≥4mm;
  • Suitable for solar photovoltaic power generation inverter: APF/SVG
  • PCB mounting;
  • The whole machine applies coil holding voltage to save energy consumption;
  • Mechanical endurance : more than 1 mln times .
  • Dimension:65*52.8*53.5(mm)
Purchase Contact
Data Download
Dear customer, hello:
If you need to consult more detailed product issues, please leave your contact information, and we will arrange professional personnel to provide you with further services. Thank you for your attention to Gretel intelligent products!

Continue downloading

Product appearance 3D structural diagram and other materials
file name remark update time
Parameters

Appearance Shell Color Black Remark
contact Contact Form 1H Normally Open
Contact Material AgNi
Contact Resistance ≤1mΩ Test according to voltammetry with 10A constant current
Rated Load (Resistive)   connect 50A,carry 300A,disconnect50A , 1000VAC Contact Load (Resistive) 250A 60VDC
Max. Switching Voltage 1000VAC Maximum switching voltage 60VDC
Max. Switching Current 300A Maximum switching current 300A
Max. Switching Power 50000VA Rated switching power 15000VA
Maximum switching power 255000VA Maximum switching power 18000VA
Note: The above values are initial values
  coil Rated Power 3W Note:(1)Coil holding voltage is the coil voltage applied to the coil over 100mS of rated voltagel;(2)The relay coil is not allowed to exceed the upper limit of the protection voltage for a long time to prevent the coil from overheating and burning out。
Holiding Voltage 40%~100%∪n(ambient temp:25℃) 50%~60%∪n(ambient temp: 85℃)
coil specification rate voltage    VDC operating voltage
  VDC
releasing voltage
VDC
Max. voltage    VDC coil resistance                                                Ω coil resistance             (high power:5W)                                                Ω
6 ≤4.2 ≥0.6 7.2 12(1±10%) 7.2✖(1±10%)
9 ≤6.3 ≥0.9 10.8 27✖(1±10%) 16.2✖(1±10%)
12 ≤8.4 ≥1.2 14.4 48✖(1±10%) 28.8✖(1±10%)
24 ≤16.8 ≥2.4 28.8 192(1±10%) 115.2✖(1±10%)
note::(1)the above values are initial values;(2)the max voltage is the max voltage which the relay coil can bear in a short time.
Performance Parameters working temp -40℃~85℃ apply holding force to coil
coil temperautre rise ≤70K contact load: 300A,50~60% rated voltage excitation,ambient temp: 85℃
operating(rated voltage) ≤30ms
releasing(rated voltage) ≤10ms
Humidity 5%-85%RH
Mechanical Vibration 10~55HZ single amplitude
 1.0mm double amplitude 
After the test, there should be no loose structure or mechanical damage, and the state of the relay can't be changed.
Mechanical
Shock
Strength 980m/S2 After the test, there should be no loose structure or mechanical damage, and the state of the relay can't be changed.
Stability 98m/S2
Surge voltage
( between coil and contact)
10KV(1.2/50∪s)
Insulation resistance ≥1000MΩ(500VDC)
Dielectric
Strength
contact-contact 3000VAC 1min No flashover, arcing or insulation breakdown is allowed during the dielectric withstand test. The leakage current shall not be greater than 1mA
Performance Parameters Dielectric
Strength
contact-coil 5000VAC 1min
Heat and fire resistance  Class F
Performance Parameters Electrical Life 3×10⁴ connect 55A, carry 300A,disconnect 55A,1000VAC, resistive load,85℃,ON: 1s,OFF: 9s
1×10² connect 300A,1000VAC, resistive load,85℃,ON: 1s,OFF:9s
Mechanical Life 1×106 The times of consecutive actions under no or light load conditions
Mounting Method PCB 
Weight about 300g
sealled structure the flux type
Note: The above values are initial values
Safety
Certificate
type test conditions
UL/CUL connect 55A, carry 300A,disconnect 55A,800VAC,85℃,30000 cycles,resistive load,ON: 1s,OFF: 9s
T∪V connect 55A, carry 300A,disconnect 55A,800VAC,85℃,30000 cycles,resistive load,ON: 1s,OFF: 9s
CQC connect 55A, carry 300A,disconnect 55A,800VAC,85℃,30000 cycles,resistive load,ON: 1s,OFF: 9s
Note:(1)For the load without temperature specified is the ambient temperature (room temperature) ;              (2)The above values   are only partial typical load parameters of products. The detailed test conditions of each load are different, so the actual electrical life times are different. (3). the above certificates are on-going.
How to order:

Dimension and Diagram(unit:mm)